FXSPAN

0116 systems
16 wall systems in four groups – from non-combustible to acoustic. Classes A2‑s1, d0 and B‑s1, d0 apply to the composite in accordance with DIN EN 13501-1.
Fire classification
Sector
4 products
Reset filters4 systems
as a composite to DIN EN 13501-1
FXSPAN

FXMPX

RWSEMDF

Real wood veneer on MDF, flame-retardant finish
RWSEMPX

Birch plywood with real wood surface
02Fire classes
The right fire classification depends on the area of use, the fire safety concept and the applicable regulations.
A2-s1, d0
B-s1, d0
Tested as a composite: the classification applies to the board as a composite of surface coating and carrier board, tested to DIN EN 13501-1.
Different fire classes can be combined within one project – for escape routes, public areas, offices or ancillary rooms, for example – while keeping a uniform surface and appearance.
| National class to DIN 4102-1 | Building authority designation | European class to DIN EN 13501-1 | No smoke | No burning droplets / particles |
|---|---|---|---|---|
| A1non-combustible | non-combustible | A1 | yes | yes |
| A2non-combustible | non-combustible | A2-s1, d0 | yes | yes |
| B1flame-retardant | flame-retardant | B-s1, d0 or C-s1, d0 | yes | yes |
| B1flame-retardant | flame-retardant | A2-s2, d0 or A2-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | B-s2, d0 or B-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | C-s2, d0 or C-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | A2-s1, d1 or A2-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | B-s1, d1 or B-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | C-s1, d1 or C-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | A2-s3, d2 / B-s3, d2 / C-s3, d2 | ||
| B2normally flammable | normally flammable | D-s1, d0 or D-s2, d0 | yes | |
| B2normally flammable | normally flammable | D-s3, d0 or E | yes | |
| B2normally flammable | normally flammable | D-s1, d1 or D-s2, d1 | ||
| B2normally flammable | normally flammable | D-s3, d1 or D-s1, d2 | ||
| B2normally flammable | normally flammable | D-s2, d2 or D-s3, d2 | ||
| B2normally flammable | normally flammable | E-d2 | ||
| B3highly flammable | highly flammable | F |
× = requirement met
03Documents
Would you like detailed information on our products? We will gladly provide the relevant data sheets. Simply send us a short message listing the products you need – we will email the documents to you promptly.
04Contact
We advise you on fire classification, applications, decors and installation.
Or give us a call+49 (0) 9941 / 90 88 50