FXSPAN

0116 systems
16 wall systems in four groups – from non-combustible to acoustic. Classes A2‑s1, d0 and B‑s1, d0 apply to the composite in accordance with DIN EN 13501-1.
Fire classification
Sector
4 products
Reset filters4 systems
as a composite to DIN EN 13501-1
FXSPAN

FXMPX

FXMDF

Flame-retardant MDF with EGGER decor
RWSEMPX

Birch plywood with real wood surface
02Fire classes
The right fire classification depends on the area of use, the fire safety concept and the applicable regulations.
A2-s1, d0
B-s1, d0
Tested as a composite: the classification applies to the board as a composite of surface coating and carrier board, tested to DIN EN 13501-1.
Different fire classes can be combined within one project – for escape routes, public areas, offices or ancillary rooms, for example – while keeping a uniform surface and appearance.
| National class to DIN 4102-1 | Building authority designation | European class to DIN EN 13501-1 | No smoke | No burning droplets / particles |
|---|---|---|---|---|
| A1non-combustible | non-combustible | A1 | yes | yes |
| A2non-combustible | non-combustible | A2-s1, d0 | yes | yes |
| B1flame-retardant | flame-retardant | B-s1, d0 or C-s1, d0 | yes | yes |
| B1flame-retardant | flame-retardant | A2-s2, d0 or A2-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | B-s2, d0 or B-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | C-s2, d0 or C-s3, d0 | yes | |
| B1flame-retardant | flame-retardant | A2-s1, d1 or A2-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | B-s1, d1 or B-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | C-s1, d1 or C-s1, d2 | yes | |
| B1flame-retardant | flame-retardant | A2-s3, d2 / B-s3, d2 / C-s3, d2 | ||
| B2normally flammable | normally flammable | D-s1, d0 or D-s2, d0 | yes | |
| B2normally flammable | normally flammable | D-s3, d0 or E | yes | |
| B2normally flammable | normally flammable | D-s1, d1 or D-s2, d1 | ||
| B2normally flammable | normally flammable | D-s3, d1 or D-s1, d2 | ||
| B2normally flammable | normally flammable | D-s2, d2 or D-s3, d2 | ||
| B2normally flammable | normally flammable | E-d2 | ||
| B3highly flammable | highly flammable | F |
× = requirement met
03Documents
Would you like detailed information on our products? We will gladly provide the relevant data sheets. Simply send us a short message listing the products you need – we will email the documents to you promptly.
04Contact
We advise you on fire classification, applications, decors and installation.
Or give us a call+49 (0) 9941 / 90 88 50