Skip to content

0116 systems

Wall systems by fire classification.

16 wall systems in four groups – from non-combustible to acoustic. Classes A2‑s1, d0 and B‑s1, d0 apply to the composite in accordance with DIN EN 13501-1.

Products

Filter products

2 products

Reset filters
A2-s1, d0

Non-combustible

2 systems

as a composite to DIN EN 13501-1

02Fire classes

What the classes mean.

The right fire classification depends on the area of use, the fire safety concept and the applicable regulations.

How the designation is built

  • A2-s1, d0

    A2
    Non-combustible (national: A2)
    s1
    No or very little smoke
    d0
    No burning droplets
  • B-s1, d0

    B
    Flame-retardant (national: B1)
    s1
    No or very little smoke
    d0
    No burning droplets

Tested as a composite: the classification applies to the board as a composite of surface coating and carrier board, tested to DIN EN 13501-1.

Different fire classes can be combined within one project – for escape routes, public areas, offices or ancillary rooms, for example – while keeping a uniform surface and appearance.

National and European classes compared

Correspondence between national classes to DIN 4102-1 and European classes to DIN EN 13501-1
National class to DIN 4102-1Building authority designationEuropean class to DIN EN 13501-1No smokeNo burning droplets / particles
A1non-combustiblenon-combustibleA1yesyes
A2non-combustiblenon-combustibleA2-s1, d0yesyes
B1flame-retardantflame-retardantB-s1, d0 or C-s1, d0yesyes
B1flame-retardantflame-retardantA2-s2, d0 or A2-s3, d0yes
B1flame-retardantflame-retardantB-s2, d0 or B-s3, d0yes
B1flame-retardantflame-retardantC-s2, d0 or C-s3, d0yes
B1flame-retardantflame-retardantA2-s1, d1 or A2-s1, d2yes
B1flame-retardantflame-retardantB-s1, d1 or B-s1, d2yes
B1flame-retardantflame-retardantC-s1, d1 or C-s1, d2yes
B1flame-retardantflame-retardantA2-s3, d2 / B-s3, d2 / C-s3, d2
B2normally flammablenormally flammableD-s1, d0 or D-s2, d0yes
B2normally flammablenormally flammableD-s3, d0 or Eyes
B2normally flammablenormally flammableD-s1, d1 or D-s2, d1
B2normally flammablenormally flammableD-s3, d1 or D-s1, d2
B2normally flammablenormally flammableD-s2, d2 or D-s3, d2
B2normally flammablenormally flammableE-d2
B3highly flammablehighly flammableF

× = requirement met

03Documents

Data sheets and catalogues.

Would you like detailed information on our products? We will gladly provide the relevant data sheets. Simply send us a short message listing the products you need – we will email the documents to you promptly.

04Contact

The right system for your project.

We advise you on fire classification, applications, decors and installation.